National standards of People's Republic of China
Plywood General technical conditions for ordinary plywood
1 Subject content and scope of application This standard specifies
the general technical conditions of ordinary plywood defined by
GB9846.2.This standard applies to plywood consisting of at least three
layers of veneer.This standard does not apply to veneer plywood and
special plywood.
2 Reference standard GB 9846.1 plywood classification GB 9846.2
Plywood terms and definitions GB 9846.3 Plywood general plywood
dimensions and tolerances technical conditions GB 9846.5 plywood general
plywood appearance grade technical conditions GB 9846.11 determination
of plywood moisture content GB 9846.12 plywood plywood strength
Determination
3 Structure of the board
Usually the wood grain of two adjacent veneers should be perpendicular to each other.
The veneers on the symmetric layers on both sides of the center layer
should be the same thickness,the same tree species or the tree species
with similar physical properties and the same production method(that
is,all are rotary cut or all sliced),and the wood grain configuration
direction should also be the same.
Two-layer veneer with parallel wood grain direction is allowed to be
combined into two layers as the center layer.When testing the bonding
strength,the two-layer veneer is regarded as one layer.
The same layer of surface board should be the same tree species,and the surface board should face tightly outward.
Non-porous adhesive tape for jointing shall not be used inside
plywood.If it is used to splice the first-and second-class panels or to
repair the cracks of the first-and second-class panels,the tape should
be removed and no obvious tape marks should be left afterwards,but the
second-class plywood panels of conifer wood are allowed to leave The
total length of the adhesive tape shall not exceed 15%of the board
length.
Under normal dry conditions,the surface thickness of the broad-leaved
plywood should not exceed 3.5 mm,and the thickness of the inner veneer
should not exceed 5 mm.The thickness of the inner layer and surface
veneer of conifer wood plywood should not exceed 6.5mm.
Veneers of each layer of plywood are not allowed to be terminated without bevel bonding or finger splicing.
There should be no inclusions in the plywood that affect the use,that
is,it does not affect the smoothness of the board surface,does not
affect the finish treatment,and does not affect the quality of the
plywood.
4 Processing quality Plywood should have right angles and straight
edges,and its dimensions and tolerances should meet the requirements of
GB9846.3.
5 Features of the watch plate
According to the appearance grade,the watch panel can be a whole
veneer,or it can be splicedtogether along the edge by several veneers
of equal or unequal width.
Stitching,color matching and allowable defects should all comply with the provisions of GB9846.5.
6 Features of inner layer veneer
The inner veneer of plywood should include splicedor non-splicedveneers of any width.
Inner layer veneer is allowed to contain material defects and
processing defects,but should be in accordance with the provisions of
GB9846.5,without affecting the appearance and applicability required for
plywood applications.
7 types
The tree species of the plywood panel is the tree species of the
plywood.a.Commonly used domestically broad-leaved tree species include
Basswood,Fraxinus
mandshurica,Birch,Lotus,Poplar,Elm,Oak,Maple,Alder,Maple,etc.:b.Commonly
used domestic shiba species are Masson pine and Yunnan
pine.Larch,spruce,etc.
Common plywood is divided into four categories.a.Class 1 plywood,that
is,weather-resistant biteboard;b.Type 2 plywood,namely water resistant
plywood;c.Type 3 plywood,namely moisture resistant plywood;d.Type 4
plywood,namely moisture resistant plywood.
8 Physical and mechanical properties
Water content
The moisture content of plywood when shipped from the factory should
meet the requirements in Table 1.Table 1 Types of moisture content of
plywood Water content of plywood species Classes 1,2 and 3,4
Broad-leaved tree wood 6~148~16 Conifer tree wood
Moisture content should be measured according to GB9846.11.
Adhesive strength
All kinds of plywood bonding strength index value according to Table 2.
The bonding strength should be determined according to the provisions of GB9846.12.
For the plywood index value of plywood made with different tree
species,the minimum index value for the plywood strength index value of
each tree species should be taken.Table 2 Glue Strength Index
ValuesCategory Plywood Tree Species Glue Strength of Single Specimens
Class 1,Class 2,Class 3,Basswood,Poplar,Alnus spp.≥0.70≥0.70 Fraxinus
mandshurica,Schima superba,Liquidambar formosana,Firewood,Elm
Wood,oak≥0.80 Birch≥1.00 Masson pine,Yunnan pine,larch,spruce≥0.80 8.2.4
When determining the conversion coefficient of the bonding strength of
the thick core veneer structure,the nominal thickness of the veneer
should be used.
The plywood strength index value of plywood made from paulownia is
compared with the index value of poplar as specified in Table 2.For
other plywood made from broad-leaved wood or coniferous village,the
plywood strength index value can be compared with that specified in
Table 2 according to their density The index value of root tree,ash or
pine.When imported Liu'an tree species are used as the inner veneer,the
value of the plywood strength shall meet the requirements for root
plywood in Table 2.If hard broad-leaved wood veneers such as
Abidong,Clone,and Cinnamomum camphora are used as the inner veneer,the
value of the bond strength index should meet the requirements for ash
plywood in the table.
When the average wood failure rate of the test piece for the
determination of the bonding strength exceeds 80%,the index value of the
bonding strength may be 0.20 MPa lower than the index value specified
in Table 2.
The judgment of the test results shall be carried out according to the following regulations:
When the number of test pieces that meet the requirements of the
bonding strength index value is equal to or greater than 80%of the total
number of effective test pieces,the strength of the glue table of the
batch of glue wrenches is judged as qualified.
When the number of test pieces that meet the requirements of the glue
strength index value is less than 80%of the total number of effective
test pieces,re-inspection is allowed once.To be qualified,if the number
of qualified test pieces for re-examination is still less than 80%of the
total number of valid test pieces,the bonding strength of the batch of
plywood is judged as unqualified.